Control register
RESP | Reset position counter. When set = 1, resets the position counter to all zeros. Autoclears when the position counter is cleared. |
RESPI | Reset position counter on index. When set = 1, resets the position counter to all zeros when an index pulse occurs. Autoclears when the position counter is cleared. |
RESV | Reset velocity. When set = 1, resets the velocity counter to all zeros and reloads the velocity timer. Autoclears when the velocity counter is cleared. |
RESI | Reset index counter. When set = 1, resets the index counter to all zeros. Autoclears when the index counter is cleared. |
RESERVED | reserved |